Product Detail :
|
SINGLE-CHAMBER TRANSCATHETER CARDIAC STIMULATION SYSTEM WITH ATRICULAR VENTRICULAR MONITORING FUNCTION COMPATIBLE WITH 3 T MAGNETIC RESONANCE.
|
| Tender Detail : |
Tenders are invited for SINGLE-CHAMBER TRANSCATHETER CARDIAC STIMULATION SYSTEM WITH ATRICULAR VENTRICULAR MONITORING FUNCTION COMPATIBLE WITH 3 T MAGNETIC RESONANCE. Programmable cardiac device that monitors and regulates the patients heart rate by delivering rate-responsive anti-bradycardia pacing to the right ventricle and AV synchrony based on mechanical detection of atrial activity. 1. Permanent stimulation modes: VVI VVIR VOO VDD and VDI. 2. Minimum frequency programmable between 30 and 170 per minute or more. 3. Programmable tracking frequency between 80 and 115 per minute or more. 4. Maximum activity sensor frequencies programmable between 80 and 170 per minute or more. 5. Voltages: Programmable between 0.13 or less, 5 volts or more. 6. Programmable pulse width or duration between 0.09 to 1 ms or more. 7. Atrial detection vector from 1 to +3 or more. 8. Atrial detection configuration: programmable. 9. Programmable ventricular sensitivity: from 0.45 mV or less to 11.30mV or more. 10. A-V detected: between 20 and 200 ms. 11. Capture control: Adaptive. 12. PVARP: automatic. 13. Activity sensor: programmable. 14. Activity mode change: programmable. 15. A-V driving mode change: programmable. 16. Temporary programming modes. 17. Holter Telemetry: Programmable. 18. Frequency hysteresis: Programmable. 19. Measurement tests: exercise stimulation threshold detection. 20. Atrial mechanical manual test: Threshold detection vector. 21. Stored data and diagnostics: 21.1. Battery voltage. 21.2. Remaining useful life. 21.3. Detection integrity meter. 21.4. Electrode impedance. 21.5. Capture threshold. 21.6. Sensing electrode impedance trend. 21.7. Capture threshold trend. 21.8. R wave amplitude trend. 21.9. Amplitude trend of A. 21.10. Frequency histogram on screen and to print. 22. Device performance trend (By 80 weeks): 22.1. Electrode impedance. 22.2. Capture threshold trend. 22.3. R wave amplitude trend. 22.4. Amplitude trend A. 23. 7.8 mm (23 Fr) introducer with 56 cm length or more. 24. With the ability to recover and relocate the device. 25. Generator: 25.1 With factory radiopaque marking for resonance. 25.2 With a weight of 1.75 grams or less. 25.3 With a volume of 0.8cc or 1cc. 25.4 With a length of 27.9 mm or less. 25.5 With external diameter of 67 mm (20.1 Fr) or smaller. 25.6 Space between cathode and anode of 18 mm or less. 25.7 Battery life of 10 years or longer with optimal stimulation parameters. 26. Compatible with 3 T MRI. Observation of the line Companies must have technical personnel available for monitor implants and for any consultation that is required at any time or day. 2. Technicians must present a training certificate in knowledge and handling of equipment in sites recognized and authorized by the manufacturer. |